Model |
CLG-100-12 |
CLG-100-15 |
CLG-100-20 |
CLG-100-24 |
CLG-100-27 |
CLG-100-36 |
CLG-100-48 |
|
DC Voltage |
12V |
15V |
20V |
24V |
27V |
36V |
48V |
|
Rated Current (Note 6) |
40A |
30A |
18A |
15A |
10A |
8A |
5A |
|
Current Range (Note 6) |
0 ~ 5A |
0 ~ 5A |
0 ~ 4.8A |
0 ~ 4A |
0 ~ 3.55A |
0 ~ 2.65A |
0 ~ 2A |
|
Rated Power (Note 6) |
60W |
75W |
96W |
96W |
95.85W |
95.4W |
96W |
|
Ripple & Noise (max.) (Note 2) |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
|
Voltage Adj. Range |
Fixed. Can be modified between 0% ~ -15% rated output voltage |
||||||
|
Current Adj. Range |
Fixed. Can be modified between 3% ~ -25% rated output current |
||||||
|
Voltage Tolerenace (Note 3) |
±3.0% |
±3.0% |
±3.0% |
±3.0% |
±3.0% |
±2.0% |
±2.0% |
|
Line Regulation |
±1.0% |
||||||
|
Load Regulation |
±2.0% |
||||||
|
Setup, Rise Time |
1200ms, 80ms / 230VAC 1200ms, 80ms / 11VAC at full load |
||||||
|
Hold Time (Typ.) |
60ms / 230VAC 30ms / 115VAC at full load |
||||||
|
Voltage Range (Note 5) |
90 ~ 264VAC |
||||||
|
Frequency Range |
47 ~ 63Hz |
||||||
|
Power Factor |
PF>0.95/230VAC PF>0.98/115VAC at full load |
||||||
|
Efficiency (Typ.) |
83% |
85% |
87% |
87% |
87% |
87% |
87% |
|
AC Current |
12V:0.8A/115VAC 0.4A/230VAC 15V:0.9A/115VAC 0.45/230VAC 20V ~ 48V:1.1A/115VAC 0.55A/230VAC |
||||||
|
In Rush Current (Max.) |
COLD START 40A/230VAC |
||||||
|
Leakage Current |
0.5mA/240VAC |
||||||
|
Over Current (Note 4) |
95 ~ 100% |
||||||
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|||||||
|
Over Voltage |
13 ~ 16V |
16.5 ~ 20V |
22 ~ 27V |
27 ~ 34V |
29 ~ 36V |
39 ~ 48V |
52 ~ 64V |
|
Protection type : Shut down and latch of o/p voltage, re-power on to recover |
|||||||
|
Over Temperature |
90°C±10°C (RTH2) |
||||||
|
Protection type : Shut down and latch of o/p voltage, re-power on to recover |
|||||||
|
Working Temp. |
-30°C ~ +70°C (Refer to output load derating curve), -40°C possible |
||||||
|
Working Humidity |
20 ~ 90% RH non-condensing |
||||||
|
Storage Temp. Humidity |
-40 ~ +80°C , 10 ~ 95% RH |
||||||
|
Temp. Coefficient |
±0.03%/°C (0 ~ 50°C) |
||||||
|
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
||||||
|
Safety Standards |
UL1310 Class 2, TUV EN60950-1, CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 Approved |
||||||
|
Withstand Voltage |
I/P-O/P:4.25KVDC |
||||||
|
Isolation Resistance |
I/P-O/P:100M Ohms/500VDC |
||||||
|
EMI Conduction & Radiation |
Compliance to EN55022 (CISPR22) Class B |
||||||
|
Harmonic Current |
Compliance to EN61000-3-2,-3 |
||||||
|
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, ENV55024, Light industry level, criteria A |
||||||
|
MTBF |
301K hrs min. MIL-HDBK-217F (25°C) |
||||||
|
Dimension |
222*68*39mm (L*W*H) |
||||||
|
Packing |
1.0Kg; 12pcs/13Kg/0.49CUFT |
||||||
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to OLP characteristics. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. This is the maximum possible output current and power, overload protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 7. 3 years warranty is guaranteed for operating ambient temperature no higher than 68°C. |
|||||||