Model |
S-100-3 |
S-100-5 |
S-100-7.5 |
S-100-10 |
S-100-12 |
S-100-15 |
S-100-18 |
S-100-24 |
S-100-27 |
S-100-48 |
|
DC Voltage |
3V |
5V |
7.5V |
10V |
12V |
15V |
18V |
27V |
27V |
48V |
|
Rated Current |
20A |
20A |
13.6A |
10A |
8.5A |
6.7A |
5.6A |
4.5A |
3.7A |
2A |
|
Current Range |
0 ~ 20A |
0 ~ 20A |
0 ~ 13.6A |
0 ~ 10A |
0 ~ 8.5A |
0 ~ 6.7A |
0 ~ 5.6A |
0 ~ 4.5A |
0 ~ 3.7A |
0 ~ 2A |
|
Rated Power |
60W |
100W |
102W |
100W |
102W |
100.5W |
100.8W |
108W |
99.9W |
96W |
|
Ripple & Noise (max.) |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
|
Voltage Adj. Range |
2.85 ~ 3.3V |
4.75 ~ 5.5V |
6.75~8.25V |
9 ~ 11V |
10.8~13.2V |
13.5~16.5V |
16.2~19.8V |
21.6~26.4V |
26 ~ 32V |
43.2~52.8V |
|
Voltage Tolerenace |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.3% |
±0.3% |
±0.3% |
±0.2% |
±0.2% |
±0.2% |
±0.2% |
|
Load Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.3% |
±0.3% |
±0.3% |
±0.2% |
±0.2% |
±0.2% |
±0.2% |
|
Setup, Rise Time |
200ms, 80ms at full load |
|||||||||
|
Hold Time |
20ms at full load |
|||||||||
|
Voltage Range |
85 ~ 132VAC/180 ~ 264VAC selected by switch 255 ~ 370VDC |
|||||||||
|
Frequency Range |
47 ~ 63Hz |
|||||||||
|
Efficiency (Typ.) |
70% |
78% |
80% |
80% |
81% |
81% |
82% |
84% |
84% |
84% |
|
AC Current (Typ.) |
2.4A/115VAC 1.2A/230VAC |
|||||||||
|
In Rush Current (Max.) |
COLD START 30A/115VAC 60A/230VAC |
|||||||||
|
Leakage Current |
<1mA / 240VAC |
|||||||||
|
Over load |
105 ~ 150% rated output power (150 ~ 200% rated output power for S-100-7.5 only) |
|||||||||
|
Protection type : Shut down o/p voltage, re-power on to recover |
||||||||||
|
Working Temp. |
-10 ~ +60°C (Refer to output load derating curve) |
|||||||||
|
Working Humidity |
20 ~ 90% RH non-condensing |
|||||||||
|
Storage Temp. Humidity |
-20 ~ +85°C , 10 ~ 95% RH |
|||||||||
|
Temp. Coefficient |
±0.03%/°C (0 ~ 50°C) |
|||||||||
|
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
|||||||||
|
Safety Standards |
Design refer to UL1012 |
|||||||||
|
Withstand Voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|||||||||
|
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
|||||||||
|
EMI Conduction & Radiation |
Design refer to FCC Part15 J Conduction Class B |
|||||||||
|
MTBF |
322.4K hrs min. MIL-HDBK-217F (25°C) |
|||||||||
|
Dimension |
199*98*38mm (L*W*H) |
|||||||||
|
Packing |
0.8Kg; 16pcs/13.8Kg/0.95CUFT |
|||||||||
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
||||||||||