Outdoor 300W Power Supply
HOME LED Lighting Architectural LED Lighting LED Lighting Controllers & Power Supplies LED Lighting Outdoor 300W Power Supply

Outdoor 300W Power Supply

Overview

  • Universal AC input / Full range
  • Protections:Short circuit/Over load/Over voltage/Over temperature
  • Built-in active PFC function
  • IP66 design for indoor or outdoor installations
  • UL1310 Class 2 power unit
  • Cooling by free air convection
  • 100% full load burn-in test
  • High realibility
  • Suitable for LED lighting and moving sign applications
  • 3 years warranty

Specifications

  • Model
  • DC Voltage
  • Rated Current
  • Current Range
  • Rated Power
  • Ripple & Noise (max.)
  • Voltage Adj. Range
  • Efficiency (Typ.)
  • Over Voltage
  • PWR-CLN-USP350-12
  • 12V
  • 29.2A
  • 0 ~ 25A
  • 300W
  • 100mVp-p
  • 10.8 ~ 13.2V
  • 88%
  • 13.5 ~ 16.3V
  • PWR-CLN-USP350-15
  • 15V
  • 23.4A
  • 0 ~ 20A
  • 300W
  • 100mVp-p
  • 13.5 ~ 16.5V
  • 88%
  • 17 ~ 21V
  • Model
  • DC Voltage
  • Rated Current
  • Current Range
  • Rated Power
  • Ripple & Noise (max.)
  • Voltage Adj. Range
  • Efficiency (Typ.)
  • Over Voltage
  • PWR-CLN-USP350-24
  • 24V
  • 14.6A
  • 0 ~ 12.5A
  • 300W
  • 150mVp-p
  • 21.6 ~ 26.4V
  • 88%
  • 26.7 ~ 32.4V
  • PWR-CLN-USP350-48
  • 48V
  • 7.3A
  • 0 ~ 6.25A
  • 300W
  • 150mVp-p
  • 43.2 ~ 52.8V
  • 89%
  • 89%
  • Voltage Tolerance
  • Line Regulation
  • Load Regulation
  • Setup, Rise Time
  • Hold Time (Typ.)
  • Voltage Range
  • Frequency Range
  • Power Factor
  • AC Current
  • In Rush Current (Max.)
  • Leakage Current
  • Over Current
  • Over Temperature
  • Working Temp.
  • Working Humidity
  • Storage Temp. Humidity
  • Temp. Coefficient
  • Vibration
  • Safety Standards
  • Withstand Voltage
  • Isolation Resistance
  • EMI Conduction & Radiation
  • Harmonic Current
  • EMS Immunity
  • MTBF
  • Dimension
  • IP Rating
  • Packing
  • ±2.0%
  • ±0.5%
  • ±1.0%
  • 2000ms, 100ms/230VAC 4000ms, 100ms/115VAC at full load
  • 16ms/230VAC 16ms/115VAC at full load
  • 90 ~ 264VAC 127 ~ 370VDC
  • 47 ~ 63Hz
  • 0.95/230VAC, 0.98/115VAC at full load
  • 4A/115VAC 2A/230VAC
  • 22A/115VAC 44A/230VAC
  • <2mA / 240VAC
  • 105 ~ 130% rated output power
  • 80°C±5°C (TSW1) detect on heatsink of power transistor, 80°C±5°C (TSW2 ) detect on heatsink of power diode
  • -10°C ~ +65°C (Refer to output load derating curve)
  • 20 ~ 90% RH non-condensing
  • -40 ~ +85°C , 10 ~ 95% RH
  • ±0.03%/°C (0 ~ 45°C)
  • 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
  • UL60950-1, TUV EN60950-1 approved
  • I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
  • I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
  • Compliance to EN55015, EN55022 (CISPR22) Class B
  • Compliance to EN61000-3-2,-3
  • Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
  • 106.3K hrs min. MIL-HDBK-217F (25°C)
  • 235.2*101.5*38mm (L*W*H
  • IP66
  • 1.3Kg; 12pcs/16.6Kg/0.74CUFT(HLG-240-Blank/A/B) 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

5. Derating may be needed under low input voltages. Please check the derating curve for more details.

Derating Curve

Outdoor 300W Power Supply Derating Curve