Outdoor 300W Power Supply
Overview
- Universal AC input / Full range
- Protections:Short circuit/Over load/Over voltage/Over temperature
- Built-in active PFC function
- IP66 design for indoor or outdoor installations
- UL1310 Class 2 power unit
- Cooling by free air convection
- 100% full load burn-in test
- High realibility
- Suitable for LED lighting and moving sign applications
- 3 years warranty
Specifications
- Model
- DC Voltage
- Rated Current
- Current Range
- Rated Power
- Ripple & Noise (max.)
- Voltage Adj. Range
- Efficiency (Typ.)
- Over Voltage
- PWR-CLN-USP350-12
- 12V
- 29.2A
- 0 ~ 25A
- 300W
- 100mVp-p
- 10.8 ~ 13.2V
- 88%
- 13.5 ~ 16.3V
- PWR-CLN-USP350-15
- 15V
- 23.4A
- 0 ~ 20A
- 300W
- 100mVp-p
- 13.5 ~ 16.5V
- 88%
- 17 ~ 21V
- Model
- DC Voltage
- Rated Current
- Current Range
- Rated Power
- Ripple & Noise (max.)
- Voltage Adj. Range
- Efficiency (Typ.)
- Over Voltage
- PWR-CLN-USP350-24
- 24V
- 14.6A
- 0 ~ 12.5A
- 300W
- 150mVp-p
- 21.6 ~ 26.4V
- 88%
- 26.7 ~ 32.4V
- PWR-CLN-USP350-48
- 48V
- 7.3A
- 0 ~ 6.25A
- 300W
- 150mVp-p
- 43.2 ~ 52.8V
- 89%
- 89%
- Voltage Tolerance
- Line Regulation
- Load Regulation
- Setup, Rise Time
- Hold Time (Typ.)
- Voltage Range
- Frequency Range
- Power Factor
- AC Current
- In Rush Current (Max.)
- Leakage Current
- Over Current
- Over Temperature
- Working Temp.
- Working Humidity
- Storage Temp. Humidity
- Temp. Coefficient
- Vibration
- Safety Standards
- Withstand Voltage
- Isolation Resistance
- EMI Conduction & Radiation
- Harmonic Current
- EMS Immunity
- MTBF
- Dimension
- IP Rating
- Packing
- ±2.0%
- ±0.5%
- ±1.0%
- 2000ms, 100ms/230VAC 4000ms, 100ms/115VAC at full load
- 16ms/230VAC 16ms/115VAC at full load
- 90 ~ 264VAC 127 ~ 370VDC
- 47 ~ 63Hz
- 0.95/230VAC, 0.98/115VAC at full load
- 4A/115VAC 2A/230VAC
- 22A/115VAC 44A/230VAC
- <2mA / 240VAC
- 105 ~ 130% rated output power
- 80°C±5°C (TSW1) detect on heatsink of power transistor, 80°C±5°C (TSW2 ) detect on heatsink of power diode
- -10°C ~ +65°C (Refer to output load derating curve)
- 20 ~ 90% RH non-condensing
- -40 ~ +85°C , 10 ~ 95% RH
- ±0.03%/°C (0 ~ 45°C)
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
- UL60950-1, TUV EN60950-1 approved
- I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
- Compliance to EN55015, EN55022 (CISPR22) Class B
- Compliance to EN61000-3-2,-3
- Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
- 106.3K hrs min. MIL-HDBK-217F (25°C)
- 235.2*101.5*38mm (L*W*H
- IP66
- 1.3Kg; 12pcs/16.6Kg/0.74CUFT(HLG-240-Blank/A/B) 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.