960W Power Supply
Overview
This high power switch mode industrial power supply is ideal for large scale installations and offers high reliability for minimal maintenance.
WARNING: The power supply has exposed primary terminals and will therefore need to be placed in a suitable enclosure.
Specifications
- Model
- DC Voltage
- Rated Current
- Current Range
- Rated Power
- Ripple & Noise (max.)
- Voltage Adj. Range
- Voltage Tolerance
- Line Regulation
- Load Regulation
- Efficiency (Typ.)
- Over Voltage
- DRT-960-24
- 24V
- 40A
- 0 ~ 40A
- 960W
- 80mVp-p
- 24 ~ 28V
- ±1.0%
- ±0.5%
- ±0.5%
- 91%
- 30 ~ 36V
- DRT-960-48
- 48V
- 20A
- 0 ~ 20A
- 960W
- 80mVp-p
- 6 ~ 9V
- ±1.0%
- ±0.5%
- ±0.5%
- 92%
- 59 ~ 66V
- Setup, Rise Time
- Hold Time
- Voltage Range
- Frequency Range
- AC Current (Typ.)
- In Rush Current (Max.)
- Leakage Current
- Over load
- Over Temperature
- Working Temp.
- Working Humidity
- Storage Temp. Humidity
- Temp. Coefficient
- Vibration
- Safety Standards
- Withstand Voltage
- Isolation Resistance
- EMI Conduction & Radiation
- Harmonic Current
- EMS Immunity
- MTBF
- Dimension
- Packing
- 200ms, 60ms/400VAC 200ms, 60ms/500VAC at full load
- 14ms/400VAC 30ms/500VAC at full load
- Three-Phase 340 ~ 550VAC (Dual phase operation possible in connecting L1,L3,FG )
- 47 ~ 63Hz
- 2A/400VAC 1.6A/500VAC
- COLD START 50A
- <3.5mA / 530VAC
- 105 ~ 125% rated output power
- 110°C±5°C (TSW1) detect on heatsink of power transistor, 85°C±5°C (TSW2) detect on heatsink of power diode
- -20 ~ +60°C (Refer to output load derating curve)
- 20 ~ 90% RH non-condensing
- -40 ~ +85°C , 10 ~ 95% RH
- ±0.03%/°C (0 ~ 50°C)
- Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
- UL508, UL60950-1, TUV EN60950-1 approved
- I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH
- Compliance to EN55011 (CISPR11), EN55022 (CISPR22), EN61204-3 Class B
- Compliance to EN61000-3-2,-3
- EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61204-3, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
- 122.5Khrs min. MIL-HDBK-217F (25°C)
- 276*125.2*100mm (W*H*D)
- 3.3Kg; 4pcs/14.2Kg/1.14CUFT
1. All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. Dual phase operation(connecting L1,L3,FG)is allowed under certain derating to output load. Please refer to the derating curves for details.