Model |
S-240-5 |
S-240-7.5 |
S-240-12 |
S-240-15 |
S-240-24 |
S-240-30 |
S-240-48 |
DC Voltage |
5V |
7.5V |
12V |
15V |
24V |
30V |
48V |
Rated Current |
40A |
30A |
18A |
15A |
10A |
8A |
5A |
Current Range |
0 ~ 40A |
0 ~ 30A |
0 ~ 18A |
0 ~ 15A |
0 ~ 10A |
0 ~ 8A |
0 ~ 8A |
Rated Power |
200W |
225W |
216W |
225W |
240W |
240W |
240W |
Ripple & Noise (max.) |
150mVp-p |
200mVp-p |
150mVp-p |
150mVp-p |
180mVp-p |
180mVp-p |
240mVp-p |
Voltage Adj. Range |
4.5 ~ 5.8V |
6 ~ 9V |
10 ~ 14V |
12 ~ 18V |
20 ~ 28V |
27 ~ 33V |
41 ~ 56V |
Voltage Tolerenace |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±1.0% |
Load Regulation |
±1.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±1.0% |
Setup, Rise Time |
1000ms, 20ms at full load |
||||||
Hold Time (Typ.) |
36ms at full load |
||||||
Voltage Range |
88 ~ 132VAC / 176 ~ 264VAC auto switch 248~370VDC |
||||||
Frequency Range |
47 ~ 63Hz |
||||||
Efficiency (Typ.) |
78% |
80% |
82% |
83% |
84% |
85% |
87% |
AC Current (Typ.) |
5A/115VAC 2.5A/230VAC |
||||||
In Rush Current (Typ.) |
15A/115VAC 30A/230VAC |
||||||
Leakage Current |
<2mA / 240VAC |
||||||
Over load |
105 ~ 135% rated output power |
||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed. |
|||||||
Over Voltage |
6 ~ 7V |
9.4 ~ 10.9V |
14.4 ~ 16.8V |
18.5 ~ 21.5V |
31.2 ~ 36V |
34.5 ~ 40.5V |
57.6 ~ 67.2V |
Protection type : Hiccup mode, recovers automatically after fault condition is removed. |
|||||||
Fan Control, O.T.P. |
RT1 ≥ 40°C FAN ON, ≤ 35°C FAN OFF, ≥ 70°C output shutdown |
||||||
Working Temp. |
-10°C ~ +60°C (Refer to output load derating curve) |
||||||
Working Humidity |
20 ~ 90% RH non-condensing |
||||||
Storage Temp. Humidity |
-20 ~ +85°C , 10 ~ 95% RH |
||||||
Temp. Coefficient |
±0.03%/°C (0 ~ 50°C) |
||||||
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
||||||
Safety Standards |
UL60950-1, TUV EN60950-1 Approved (7.5V Design refer to TUV EN60950-1) |
||||||
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
||||||
EMI Conduction & Radiation |
Compliance to EN55022 (CISPR22) Class B |
||||||
Harmonic Current |
Compliance to EN61000-3-2,-3 |
||||||
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A |
||||||
MTBF |
179.3K hrs min. MIL-HDBK-217F (25°C) |
||||||
Dimension |
190*93*65mm (L*W*H) |
||||||
Packing |
1.2Kg; 12pcs/15.3Kg/0.78CUFT |
||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
|||||||


| Home > Products > Architectural LED Lighting > Controllers and Power Supplies > 240W Power Supply | |
240W Power Supply Specifications |
|
|
Webmail
Home
Industrial
Architectural
Commercial
@home
Gallery
LEDucation
FAQ
Contact
Site Map |
|