Model |
S-150-5 |
S-150-7.5 |
S-150-9 |
S-150-12 |
S-150-13.5 |
S-150-15 |
S-150-24 |
S-150-27 |
S-150-48 |
DC Voltage |
5V |
7.5V |
9V |
12V |
13.5V |
15V |
24V |
27V |
48V |
Rated Current |
30A |
20A |
16.7A |
12.5A |
11.2A |
10A |
6.5A |
5A |
3.2A |
Current Range |
0 ~ 30A |
0 ~ 20A |
0 ~ 16.7A |
0 ~ 12.5A |
0 ~ 11.2A |
0 ~ 10A |
0 ~ 6.5A |
0 ~ 5.6A |
0 ~ 3.2A |
Rated Power |
150W |
150W |
150.3W |
150W |
151.2W |
150W |
156W |
151.2W |
153.6W |
Ripple & Noise (max.) |
150mVp-p |
180mVp-p |
180mVp-p |
180mVp-p |
180mVp-p |
180mVp-p |
240mVp-p |
240mVp-p |
240mVp-p |
Voltage Adj. Range |
4.5 ~ 5.5V |
6 ~ 8.3V |
8 ~ 10.4V |
10.6 ~ 13.2V |
12 ~ 15V |
13.5 ~ 16.5V |
21 ~ 28V |
24 ~ 30V |
43 ~ 53V |
Voltage Tolerenace |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Line Regulation |
±0.5% |
±0.5% |
±0.3% |
±0.3% |
±0.3% |
±0.3% |
±0.2% |
±0.2% |
±0.2% |
Load Regulation |
±0.5% |
±0.5% |
±0.3% |
±0.3% |
±0.3% |
±0.3% |
±0.2% |
±0.2% |
±0.2% |
Setup, Rise Time |
100ms, 50ms at full load |
||||||||
Hold Time (Typ.) |
28ms at full load |
||||||||
Voltage Range |
88 ~ 132VAC/176 ~ 264VAC selected by switch 248 ~ 370VDC |
||||||||
Frequency Range |
47 ~ 63Hz |
||||||||
Efficiency (Typ.) |
78% |
80% |
80% |
82% |
83% |
84% |
85% |
86% |
87% |
AC Current (Typ.) |
3.2A/115VAC 1.6A/230VAC |
||||||||
In Rush Current (Typ.) |
COLD START 35A |
||||||||
Leakage Current |
<3.5mA / 240VAC |
||||||||
Over load |
105 ~ 150% rated output power |
||||||||
Protection type : Shut down o/p voltage, re-power on to recover |
|||||||||
Over Voltage |
5.75~6.75V |
8.63~0.13V |
10.35~12.2V |
13.8~16.2V |
15.53~18.2V |
17.25~20.3V |
30~34.8V |
31.1~36.45V |
55.2~64.8V |
Protection type : Shut down o/p voltage, re-power on to recover |
|||||||||
Working Temp. |
-10 ~ +60°C (Refer to output load derating curve) |
||||||||
Working Humidity |
20 ~ 90% RH non-condensing |
||||||||
Storage Temp. Humidity |
-20 ~ +85°C , 10 ~ 95% RH |
||||||||
Temp. Coefficient |
±0.03%/°C (0 ~ 50°C) |
||||||||
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
||||||||
Safety Standards |
UL1012, UL60950-1, TUV EN60950-1 Approved |
||||||||
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||||||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
||||||||
EMI Conduction & Radiation |
Compliance to EN55022 (CISPR22) Class B |
||||||||
Harmonic Current |
Compliance to EN61000-3-2,-3 |
||||||||
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A |
||||||||
MTBF |
286.7K hrs min. MIL-HDBK-217F (25°C) |
||||||||
Dimension |
199*110*50mm (L*W*H) |
||||||||
Packing |
0.8Kg; 16pcs/13.8Kg/0.95CUFT |
||||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
|||||||||